This gauge gives a local reading at the point where a technician is working - oil pressure, tank pressure or line pressure. It is not a precision instrument, but it is the one that decides whether the machine is behaving, so a gauge reading two bar off sends every later diagnosis in the wrong direction.
Match the range, the thread and the mounting position - a gauge fitted upside down will not be readable in service. Check whether the case is glycerine filled, since the two types are not interchangeable on a vibrating machine. If two gauges on the same machine disagree, fit a known-good gauge to both ports before ordering anything.