Part information
|
Part No |
50725016-015 |
|
Model |
PT-306-16 |
|
Brand |
SCR |
|
Origin |
China |
|
Weight |
0.5 kg |
|
HS Code |
8414909090 |
|
Lead time |
1-2weeks |
What it does
The PT-306-16 is a 0.5 kg transmitter threaded into the discharge line. The controller uses its signal to decide when to load and unload; if the signal drifts, the machine either over-pressurises or delivers less air than it should, and neither shows up as a sensor fault on the display.
Signs it needs replacing
Replacement interval
No fixed interval. Replace when the reading deviates from a reference gauge, or when the output becomes intermittent.
How to replace
Genuine vs alternative
The genuine PT-306-16 has the range and output scaling the SCR program expects. A transmitter with a different range fits the same thread and reads a believable but wrong number.
Ordering notes
Confirm the range on the old sensor label when ordering; the housing is shared across more than one range. Lead time is 1-2 weeks.