This drain solenoid valve opens on the controller's timer to blow condensate out of the separator tank or a trap. It has to seal tight between cycles and open fully on command, so the seat and the coil are both wear items.
Listed under part number 47677733001. Check the coil voltage and the timer setting before ordering. A drain that opens too briefly leaves condensate in the tank; one that stays open wastes air.