This spring-loaded safety valve is the last line of protection for the separator tank. It is set to lift at a fixed pressure stamped on the body, and it is not a working pressure regulator. Set pressure and connection size have to match the vessel rating.
Listed under part number 47613554004. Never adjust the set screw to cure a nuisance lift. Find the cause first: a stuck unload valve, a faulty pressure sensor or a blocked separator will all make a good safety valve open early.