A safety valve protects the separator tank and the downstream system against over-pressure. The spring is calibrated to the stamped set pressure, so the valve should stay shut through the whole normal operating range and only lift if something else has failed.
Listed under part number 24468027. Never adjust the set screw to cure a nuisance lift. Find the cause first: a stuck unload valve, a faulty pressure sensor or a blocked separator will all make a good safety valve open early.