This cylinder converts control air pressure into the stroke that opens or closes the inlet valve. Its seals are the wearing parts: once they pass air, the stroke gets slow and the machine stops reaching full capacity because the poppet never opens completely.
Measure the bore, the stroke and the rod thread against the old cylinder, and check the mounting pattern. If the old rod is bent, find out why before fitting a new one - a misaligned linkage will bend it again.