This is the coalescing element that separates oil from compressed air before the air leaves the tank. Gravity handles the large droplets; the media handle the mist that would otherwise travel into the aftercooler, the dryer and the plant. Because it degrades gradually, the first sign is usually oil consumption, not a pressure problem.
Check the minimum pressure valve and the scavenge line orifice before blaming the element: a blocked return line produces exactly the same oil-carryover symptom, and a new element will not fix it. Match the element by part number and by height, since two elements can share a diameter.