The air filter is the only barrier between the airend and everything the machine inhales. A screw compressor moves several cubic metres of air a minute through this element, so the pleats load quickly in a workshop with grinding dust, paint mist or a nearby road. Once the element restricts, the machine loses capacity before it shows any other fault.
The element is matched to the housing by part number; where the housing runs a safety element, change both if the primary has collapsed. If the old element came out wet or crushed, check the housing drain and the rain cap before fitting the new one.